BF-8803A integrated heat collection circulation and heating controller is incorporated with a temperature controller and a temperature difference controller, and can be used to detect both high temperature (HT) and low temperature (LT) at two points (HT for collector plate and LT for water tank).
When the [LT sensor] is used alone, one-channel temperature control outputs can be generated. When the two [HT & LT] sensors are used simultaneously, two-channel temperature difference circulation can be controlled based on the temperature difference between these two sensors.
In the temperature difference control mode, the anti-freeze circulation function will be activated when a low temperature is detected on the collector plate, and the temperature difference control output is NO. In the temperature control mode, the outputs are NO and NC.
Thanks to the wide range of rated power supply, the controller is able to ensure stable, reliable and durable operation by adapting to AC80V~240V power supply.
Two-channel 240K NTC temperature sensor input
One-channel NO/NC contacts output, two-channel NO contact output
Constant-temperature heating
Manual heating
Temperature difference circulation
Manual temperature difference circulation
Collector plate anti-freeze circulation
Real-time display of temperatures in HT and LT zones
Temperature measurement deviation correction
Memory protection after power failure
Packing List of Product |
1. Main unit 2. 2 x NTC (240K) temperature sensing wires 3. User instructions 4. Mounting bracket |
Overall Dimensions (mm) |
58 (L) × 78 (W) × 85 (T) |
Installation and Dimensions (mm) |
Window-mounted, opening size: 51 (L) ×71 (W) |
Weight |
Net weight: 0.278Kg Gross weight: 0.344Kg |
Power Supply and Consumption Power |
AC (80~240)V, 2W |
Operating Conditions |
-10℃~ 50℃ |
Display Mode | LED digital display |
Keys |
Push-type membrane keys |
Input |
Two-channel (240K) NTC thermistor temperature sensor input, measurement range: -20 ℃~120 ℃ |
Output |
1. One-channel relay NO/NC contact temperature control outputs; two-channel relay NO/NC contact temperature difference circulation outputs 2. Current capacity of each output contact: 6 A (resistive load) and 1 A (inductive load) Able to control a 1000W electric heater or a 200W motor or water pump. AC contactor required for capacity expansion in case of larger load. |
Measurement Range |
Display range of measurement in HT zone: 0~120 ℃ Display range of measurement in LT zone: 0~99 ℃ |
Setting Range |
Range of temperature control value: upper limit 0~90 ℃, lower limit 0~90 ℃ Range of temperature difference value: upper limit 2~30 ℃, lower limit 1~30 ℃ |
Control Range |
Range of temperature control value: upper limit 0~90 ℃, lower limit 0~90 ℃ Range of temperature difference value: upper limit 2~30 ℃, lower limit 1~30 ℃ |
Other Parameters |
1. Temperature sensing wire can be extended by 100 m with ordinary wire for long-distance connection 2. Memorize the set parameter for a long time after power failure |
Welcome your suggestions, please fill in the form below to send your message.
Legal statement: our products have applied for a patent or are in the process of patent application, all products are our company's research and development, we have all products of the program source code and the original design information, any copying and counterfeiting, once found, will be subject to legal action! Advocate originality, resist imitation.