BF-200A+ upper/lower limit temperature controller can be widely used for solar heat pump water heating, and various applications requiring heating control.
For one-channel temperature measurement, BESFUL NTC-220 thermistor is used to measure temperature with a display accuracy up to 0.1 ℃, allowing users to intuitively monitor the temperature rise and fall trends. For one-channel output, a relay (NO/NC contact) is controlled to output temperature control within the range of 0 ℃~120 ℃. It is easy to set up these parameters by directly adjusting the upper and lower limits to the desired values.
Thanks to the wide range of rated power supply, the controller is able to ensure stable, reliable and durable operation by adapting to AC80V~240V power supply.
One-channel temperature measurement, one-channel relay for temperature control, with NO/NC contact output
Temperature display accurate to 0.1 ℃
Memorize the set parameter for a long time after power failure
Imported NTC 240K temperature sensor for stable and reliable measurement
No compensation required for long-distance (100 m) measurement by the temperature sensor
Switch mode power supply, ensuring stable running with AC80-240V power supply
Packing List of Product | 1. Main unit 2. 1 x NTC (240K) temperature sensing wire 3. User instructions 4. Mounting bracket |
Overall Dimensions (mm) |
L 72 × W 72 × D 60 |
Installation and Dimensions (mm) |
Window-mounted, opening size: 68×68 |
Weight |
Net weight: 0.168 Kg Gross weight: 0.230 Kg |
Power Supply and Consumption Power |
AC (80~240)V, 2W |
Operating Conditions |
-10℃ ~ 50℃ |
Display Mode |
4-digit LED digital display, accuracy 0.1C |
Keys |
Push-type membrane keys |
Input |
One-channel (240K) NTC thermistor temperature sensor input, measuring range: -20.0 ℃~120.0 ℃ |
Output |
1. One-channel relay NO/NC contact output for temperature control; 2. Current capacity of relay contact: 6 A (resistive load) and 1 A (inductive load) Able to control 1000W electric heating equipment or 200W motors or water pumps. AC contactors should be used to increase the capacity for larger loads. |
Measurement Range |
-20.0 ℃~120.0 ℃ |
Setting Range |
0 ℃~120 ℃ |
Control Range |
0 ℃~120 ℃ |
Other Parameters |
1. Temperature sensing wire can be extended by 100 m with ordinary wire for long-distance connection. 2. Memorize the set parameter for a long time after power failure 3. Temperature control hysteresis: 0 ℃~30 ℃. |
(产品已申请专利,仿冒必究)
Welcome your suggestions, please fill in the form below to send your message.
Legal statement: our products have applied for a patent or are in the process of patent application, all products are our company's research and development, we have all products of the program source code and the original design information, any copying and counterfeiting, once found, will be subject to legal action! Advocate originality, resist imitation.