BF-D110A single-channel temperature controller, integrated with dual functions of heating and cooling, can be widely used in various applications requiring energy-saving and environment-friendly temperature control and cooling temperature control.
The controller can be mounted on a standard guide rail and is an ideal solution for limited space due to its compact construction.10K NTC thermistor is used for temperature measurement and can be extended by 100 m with ordinary wire for long-distance measurement, without compromising its accuracy.
Thanks to the wide range of designed supply voltage, the controller is able to ensure stable, reliable and durable operation by adapting to AC80V~240V power supply.
Delay start/stop time of compressor in refrigeration mode can be adjuste
Using flash memory technology to memorize the set parameter for a long time after power failure
Temperature-sensing head with dual rubber sealing, ensuring a certain degree of moisture resistance
Rail-mounted design to enable installation on the standard guide rail in an electric cabinet
Switch mode power supply, ensuring stable running with AC80-240V power supply
Packing List of Product |
1. Main unit 2. 1 x NTC (10K) temperature sensing wire 3. User instructions |
Overall Dimensions (mm) |
L 91 × W 40 × H 52 |
Installation and Dimensions (mm) |
The controller can be installed on a standard DIN guide rail or permanently mounted with two fixing holes (hole pitch = 84 mm). |
Weight |
Net weight: 0.152 Kg Gross weight: 0.201 Kg |
Power Supply and Consumption Power |
AC(80~240)V,2W |
Operating Conditions |
-10℃~50℃ |
Display Mode | 3-digit LED digital display |
Keys |
Push-type membrane keys |
Input |
One-channel (10K) NTC thermistor temperature sensor input, measuring range -50 ℃~120 ℃ |
Output |
1. One-channel relay NO/NC contact heating/cooling output 2. Current capacity of output contact: 5 A (resistive load) and 1 A (inductive load) Able to control 1000W electric heating equipment or 200W motors or water pumps. AC contactors should be used to increase the capacity for larger loads. |
Measurement Range |
-50 ℃~120 ℃ |
Setting Range |
Minimum limit: -45 ℃~control temperature Maximum limit: control temperature ~110 ℃ |
Control Range |
-45~110 ℃ |
Other Parameters |
1. Temperature sensing wire can be extended by 100 m with ordinary wire for long-distance connection 2. Memorize the set parameter for a long time after power failure 3. Temperature control hysteresis: 1~30 ℃ 4. Delay time: 0~5 5. Deviation correction: -15~15℃ |
Welcome your suggestions, please fill in the form below to send your message.
Legal statement: our products have applied for a patent or are in the process of patent application, all products are our company's research and development, we have all products of the program source code and the original design information, any copying and counterfeiting, once found, will be subject to legal action! Advocate originality, resist imitation.